1.
J Adhes Dent ; 25(1): 231-240, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37975312

RESUMO

PURPOSE: To conduct a systematic review and meta-analysis of in-vitro bond strength to glass-ceramics using hydrofluoric acid (HF) at lower (<5%) and higher (>5%) concentrations ([HF]) to treat ceramic surfaces. METHODS: Systematic searches were carried out in PubMed, Scopus, LILACS, and Web of Science for articles published through July 2021, and a meta-analysis was performed to estimate the combined effect by comparing the differences between the standardized means of the bond strengths of the evaluated materials. RESULTS: In total, 943 articles were found, of which 17 studies were selected for qualitative analysis and 12 for quantitative analysis. The bond strength to glass-ceramics using 4% to 5% HF did not differ from that using 7% to 10% HF for the following HF etching times and glass-ceramic materials: 20 s for lithium-disilicate (Z = 0.65, p = 0.51), 60 s for feldspathic (Z = 0.53, p = 0.60), and 60 s for leucite (Z = 0.72, p = 0.35). CONCLUSION: The lower concentration HF (<5%) etchant is a reliable surface treatment for adhesive bonding to glass-ceramics with satisfactory bond strength in short-term evaluations.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Condicionamento Ácido do Dente , Cimentos de Resina/química , Propriedades de Superfície , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química
2.
Arch Oral Biol ; 154: 105763, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37437424

RESUMO

OBJECTIVE: To evaluate the influence of Streptococcus oralis supernatant on the proliferation and virulence of Candida albicans. DESIGN: S. oralis supernatant was obtained by filtration of overnight cultures. Single or dual-species cultures of C. albicans and S. oralis were cultivated in both planktonic and biofilm-based models. Planktonic culture growth was measured, and mature biofilms formed on resin disks were collected to measure biofilm metabolic activity, total biomass, and cell counts. Hyphae formation (virulence factor) and biofilm thickness were analyzed by confocal laser scanning microscopy. Data were analyzed by a one-way ANOVA test followed by the Tukey posthoc test (α = 0.05). RESULTS: We found that S. oralis supernatant did not influence C. albicans proliferation in planktonic cultures. However, biofilms containing S. oralis supernatant showed higher cell metabolism than C. albicans monoculture biofilms and C. albicans-S. oralis dual-culture biofilms (p < 0.05). Though S. oralis supernatants did increase biofilm metabolic activity, they did not affect the total biomass and cell counts of C. albicans (p > 0.05). However, biofilm imaging revealed enhanced C. albicans hyphae formation in biofilms containing S. oralis supernatant compared to C. albicans monoculture biofilms. CONCLUSIONS: Secreted metabolites in S. oralis supernatant may contribute to C. albicans metabolism and virulence.


Assuntos
Candida albicans , Streptococcus oralis , Virulência , Biofilmes , Proliferação de Células
3.
Microorganisms ; 11(6)2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37374893

RESUMO

Candida albicans and Streptococcus mutans are known to synergistically interact with each other in the oral cavity. For example, glucosyltransferase B (GtfB), secreted by S. mutans, can bind to the C. albicans cell surface, promoting dual-species biofilm formation. However, the fungal factors mediating interactions with S. mutans are unknown. The C. albicans adhesins Als1, Als3, and Hwp1 are key players in C. albicans single-species biofilm formation, but their roles, if any, in interacting with S. mutans have not been assessed. Here, we investigated the roles of the C. albicans cell wall adhesins Als1, Als3, and Hwp1 on forming dual-species biofilms with S. mutans. We assessed the abilities of the C. albicans wild-type als1Δ/Δ, als3Δ/Δ, als1Δ/Δ/als3Δ/Δ, and hwp1Δ/Δ strains to form dual-species biofilms with S. mutans by measuring optical density, metabolic activity, cell enumeration, biomass, thickness, and architecture of the biofilms. We observed that the C. albicans wild-type strain formed enhanced dual-species biofilms in the presence of S. mutans in these different biofilm assays, confirming that C. albicans and S. mutans synergistically interact in the context of biofilms. Our results reveal that C. albicans Als1 and Hwp1 are major players in interacting with S. mutans, since dual-species biofilm formation was not enhanced when the als1Δ/Δ or hwp1Δ/Δ strains were cultured with S. mutans in dual-species biofilms. Als3, however, does not seem to play a clear role in interacting with S. mutans in dual-species biofilm formation. Overall, our data suggest that the C. albicans adhesins Als1 and Hwp1 function to modulate interactions with S. mutans and could be potential targets for future therapeutics.

4.
J Prosthet Dent ; 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36841707

RESUMO

STATEMENT OF PROBLEM: Rehabilitation with wide-diameter reduced-length implants has become popular for patients with minimal vertical bone. However, a consensus on the benefits of this approach is lacking. PURPOSE: The purpose of this systematic review with meta-analysis was to evaluate the influence of wide compared with regular diameter on the clinical performance of short (<10 mm) and extrashort (≤6 mm) dental implants used for rehabilitations with single crowns, fixed partial dentures, or both, in the posterior region. MATERIAL AND METHODS: A search in 6 databases was conducted to select randomized controlled trials (RCTs) and nonrandomized controlled trials (N-RCTs). Five meta-analyses were performed, where the risk ratio (RR) was evaluated. The certainty of evidence was evaluated, and the risk of bias was determined from the Joanna Briggs Institute checklist. RESULTS: Fourteen articles were included, 272 wide- and 478 regular-diameter implants. One study presented a low, 3 an unclear, and 11 a high risk of bias. Meta-analyses showed no statistical difference: implant survival, short dental implants in N-RCTs (up to 1 year - RR 1.01 [0.98; 1.03], 1 to 5 years - RR 1.01 [0.94; 1.08], more than 5 years - RR 1.01 [0.97; 1.06]), extrashort dental implants in N-RCTs (RR 1.04 [0.90; 1.20]), RCTs (RR 1.05 [0.88; 1.25]); implant success in N-RCTs (RR 1.01 [0.97; 1.05]); prosthesis success in N-RCTs (RR 1.01 [0.97; 1.05]). CONCLUSIONS: Short and extrashort dental implants with a wide and regular diameter appear to be clinically appropriate options for implant-supported posterior restorations, with high survival, success, and prosthesis success rates.

5.
J Prosthet Dent ; 130(2): 229-237, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34756607

RESUMO

STATEMENT OF PROBLEM: The simplified technique has been recommended for the fabrication of removable complete dentures. However, a consensus regarding the performance of the simplified and the traditional techniques is lacking. PURPOSE: The purpose of this randomized clinical trial was to compare the performance of prostheses fabricated with the simplified and the traditional techniques. MATERIAL AND METHODS: Sixty participants were recruited and randomized into 2 groups: traditional technique (control group) and simplified technique (experimental group). The assessments were performed before treatment (baseline) and 2 and 4 months after adaptation to the new complete dentures. The variables evaluated were satisfaction, oral health-related quality of life (OHRQoL) by using the Brazilian version of the OHIP-EDENT, the quality of the prostheses, and, for the functional assessment, the masticatory performance and swallowing threshold. The data were analyzed by the Fisher exact test, the Mann-Whitney test, and the generalized equations estimating (GEE) method. RESULTS: At baseline, the mean ±standard deviation quality of the prostheses was 5.3 ±2.3 for the traditional technique and 4.9 ±2.3 for the simplified technique, and at 4 months, it was 9.3 ±0.9 and 9.1 ±0.9, respectively. For masticatory performance, the mean ±standard deviation X50 at baseline was 5.7 ±1.4 for the traditional technique and 5.7 ±0.9 for the simplified technique, and at 4 months, it was 3.8 ±1.2 and 3.7 ±0.9, respectively. The mean ±standard deviation OHRQoL at baseline was 14.1 ±8.6 for the traditional technique and 12.5 ±9.4 for the simplified technique, and at 4 months, it was 3.2 ±4.3 and 2.6 ±5.1, respectively. The mean ±standard deviation satisfaction at baseline was 9.5 ±3.9 for the traditional technique and 9.3 ±4.2 for the simplified technique; after 4 months, it was 14.8 ±2.0 for both techniques. There was a significant improvement (P<.05) for all variables in the study when comparing them at the baseline to those at the evaluation after provision of new complete dentures. There was no significant difference in all analyzed variables (P>.05) between the 2 techniques for prosthesis fabrication. CONCLUSIONS: The simplified technique appears to be a suitable alternative to the traditional technique for the fabrication of complete dentures, with similar performance.


Assuntos
Satisfação do Paciente , Qualidade de Vida , Humanos , Prótese Total , Prótese Parcial , Brasil , Mastigação
6.
Braz. j. oral sci ; 22: e238152, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1437694

RESUMO

Aim: This study evaluated the influence of a wide diameter on extra-short dental implant stress distribution as a retainer for single implant-supported crowns in the atrophic mandible posterior region under axial and oblique load. Methods: Four 3D digital casts of an atrophic mandible, with a single implant-retained crown with a 3:1 crown-to-implant ratio, were created for finite element analysis. The implant diameter used was either 4 mm (regular) or 6 mm (wide), both with 5 mm length. A 200 N axial or 30º oblique load was applied to the mandibular right first molar occlusal surface. The equivalent von Mises stress was recorded for the abutment and implant, minimum principal stress, and maximum shear stress for cortical and cancellous bone. Results: Oblique load increased the stress in all components when compared to axial load. Wide diameter implants showed a decrease of von Mises stress around 40% in both load directions at the implant, and an increase of at least 3.6% at the abutment. Wide diameter implants exhibited better results for cancellous bone in both angulations. However, in the cortical bone, the minimum principal stress was at least 66% greater for wide than regular diameter implants, and the maximum shear stress was more than 100% greater. Conclusion: Extra-short dental implants with wide diameter result in better biomechanical behavior for the implant, but the implications of a potential risk of overloading the cortical bone and bone loss over time, mainly under oblique load, should be investigated


Assuntos
Implantes Dentários , Arcada Parcialmente Edêntula , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos
7.
J Prosthet Dent ; 2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35931572

RESUMO

STATEMENT OF PROBLEM: Evidence regarding the retention system for a mandibular overdenture is important for treatment planning. However, the clinical performance of stud and ball attachments for mandibular overdenture retainers is unclear. PURPOSE: The purpose of this systematic review and meta-analysis was to compare the clinical performance and self-reported patient outcomes of ball and stud attachments as mandibular overdenture retainers. MATERIAL AND METHODS: Randomized (RCTs) and nonrandomized (N-RCTs) controlled clinical trials were selected based on the eligibility criteria. The risk of bias was assessed by using the Cochrane Collaboration Tools, and the certainty of the evidence (COE) by using the grades of recommendation, assessment, development, and evaluation (GRADE) workshop approach. Meta-analyses according to the follow-up period were performed for implant survival, prosthetic maintenance and complications, bleeding on probing (BoP), marginal bone loss (MBL), satisfaction, and oral health-related quality of life (OHRQoL). RESULTS: Thirteen RCTs and 4 N-RCTs were included. Twelve studies presented a high risk of bias. The stud demonstrated a lower risk ratio (RR) (P<.001) for maintenance and complications concerning the need for matrix activation (RR 7.12 [2.65, 19.15]) (very low COE) and new overdentures (RR 2.47 [1.02, 5.96]) (moderate COE), ranging from 1 to 5 years of follow-up. Mean difference (MD) for MBL after 1 (MD 0.40 [0.28, 0.52]; P<.001) and 5 years (MD 0.18 [0.16, 0.20]; P<.001) was higher for ball attachments than that for stud (very low COE) attachments. Stud attachments also improved satisfaction (P<.001) when compared with ball attachments (very low COE). Implant survival rate (high COE), BoP (very low COE), and OHRQoL (low COE) were similar for the attachments. CONCLUSIONS: Stud and ball attachments are clinically appropriate options as mandibular overdenture retainers and are capable of restoring OHRQoL. Nevertheless, the stud showed greater improvement in satisfaction and less prosthetic aftercare and MBL.

8.
Braz Oral Res ; 36: e081, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35946733

RESUMO

This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.


Assuntos
Revestimento de Dentadura , Qualidade de Vida , Idoso , Prótese Dentária Fixada por Implante/efeitos adversos , Feminino , Humanos , Estudos Longitudinais , Mandíbula , Saúde Bucal , Satisfação do Paciente , Inquéritos e Questionários
9.
J Prosthet Dent ; 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35864024

RESUMO

STATEMENT OF PROBLEM: Implant-supported single crowns are more prone to screw loosening than splinted prostheses. Therefore, the locking taper system, which has a screwless abutment, may perform better when associated with this type of rehabilitation. However, systematic reviews on this system are lacking. PURPOSE: The purpose of this systematic review was to evaluate the clinical performance and complications of single crowns retained by the locking taper system. MATERIAL AND METHODS: This systematic review was registered at the International Prospective Register of Systematic Reviews (PROSPERO) under CRD42020189921. An electronic search was made in 5 databases and 3 other sources up to February 2021 to select prospective clinical studies evaluating the performance of single crowns retained by the locking taper system by using the outcomes implant survival, success rate, complications, marginal bone loss (MBL), and prosthesis success rate. Four meta-analyses grouped according to the follow-up intervals were performed. The risk of bias of the selected studies was evaluated by using the RoB 2 checklist for randomized controlled trials (RCTs) and Downs and Black for uncontrolled studies. RESULTS: Twelve studies were included: 9 prospective cohort studies and 3 RCTs. A survival rate of 99% (98% to 99%) and a success rate of 97% (92% to 99%) after 5 years were found. Of the total, 2.6% biological and 2.9% prosthetic complications were described. The prosthesis success rate was 97% (96% to 98%) after 5 years. An average of -0.73 mm (-0.93 to -0.52) was found for the MBL after 5 years. The risk-of-bias assessment showed 2 RCTs with high risk and 1 RCT with low risk of bias. Among uncontrolled studies, 2 were classified as poor and 7 as fair. CONCLUSIONS: Single crowns retained by locking taper implants can be safely indicated based on the high survival and success rates achieved in the long term, the maintenance of bone level stability over time, and the low incidence of complications.

10.
J Prosthet Dent ; 2022 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-35705432

RESUMO

STATEMENT OF PROBLEM: Information on the survival and mode of failure of endodontically treated incisors without a ferrule and restored without dowels is lacking. PURPOSE: The purpose of this in vitro study was to compare the survival and failure mode of endodontically treated incisors without a ferrule and restored with bonded ceramic crowns and various composite resin foundation restorations without dowels with a control group with fiber dowels. MATERIAL AND METHODS: Forty-five decoronated endodontically treated bovine incisors without ferrule were divided into 3 experimental groups and restored with different adhesive foundation restorations without dowel: nanohybrid composite resin (Nd), bulk-fill composite resin foundation restoration (NdB), and fiber-reinforced bulk-fill composite resin (NdFR). A control group with conventional foundation restorations (glass-fiber dowel with nanohybrid composite resin foundation restoration without ferrule) (D) was included for comparison. All teeth were prepared to receive bonded lithium disilicate ceramic crowns luted with dual-polymerizing composite resin cement and were subjected to accelerated fatigue testing. Cyclic isometric loading was applied to the incisal edge at an angle of 30 degrees and a frequency of 5 Hz, beginning with a load of 100 N (5000 cycles). A 100-N load increase was applied each 15 000 cycles. Specimens were loaded until failure or to a maximum for cycles endured of 1000 N (140 000 cycles). Groups were compared by using the Kaplan-Meier survival analysis (log rank test at α=.05 and pairwise post hoc comparisons) and life table analysis for load-at-failure (followed by Wilcoxon pairwise comparison α=.05). RESULTS: All the specimens failed before 140 000 load cycles. Even though no statistically significant differences were found between the experimental groups without dowel (P>.127), the fiber-reinforced foundation restoration yielded the highest mean ±standard deviation cycles to failure (46 023 ±4326) compared with Nd (38 899 ±2975) and NdB (39 751 ±2998). NdFR, however, outperformed the foundation restoration with glass-fiber dowel (35 026 ±2687) (P<.05). Most failure in groups without dowel were restorable, while 100% of catastrophic failure (unrestorable) were found in the group with dowels. CONCLUSIONS: Based on the present in vitro study, dowels did not improve the performance of the adhesive restoration of endodontically treated incisors without a ferrule. The use of a short fiber-reinforced composite resin foundation restoration without a dowel was able to not only improve the resistance of the restorations compared with adhesive foundation restorations with dowels but also minimize catastrophic failures.

11.
Toxins (Basel) ; 14(3)2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35324657

RESUMO

Botulinum neurotoxin type A1 (BoNT-A) reduces the peripheral peptide and cytokine upregulation in rats with antigen-evoked persistent immunogenic hypersensitivity (PIH) of the temporomandibular joint (TMJ). Herein, we examined the effects of two preparations of BoNT-A, abobotulinumtoxinA (aboBoNT-A; Dysport) and onabotulinumtoxinA (onaBoNT-A; Botox), on spontaneous and evoked nociceptive behaviors, as well as on central neuronal and astroglial activation. The antigen-evoked PIH was induced in rats via repeated systemic and unilateral intra-articular (i.a.) injections of methylated bovine serum albumin (mBSA). Rats were subsequently injected with unilateral i.a. aboBoNT-A (14 U/kg), onaBoNT-A (7 U/kg), or the vehicle (saline). After i.a. treatments, spontaneous and mechanically evoked nocifensive behaviors were assessed before and after the low-dose i.a. formalin (0.5%) challenge. The central effects of BoNT-A were assessed by an immunohistochemical analysis of cleaved synaptosomal-associated protein 25 (cSNAP-25) presence, c-Fos, GFAP, and CGRP expression in the trigeminal nucleus caudalis (TNC). Both BoNT-A preparations similarly reduced the formalin-induced spontaneous pain-related behaviors and mechanical allodynia of the hypernociceptive rats. Likewise, their effects were associated with the central occurrence of cSNAP-25 and reduction of c-Fos and GFAP upregulation in the TNC. BoNT-A antinociceptive activity on the PIH is associated with the toxin axonal transport to trigeminal sensory areas and reduction of neuronal and glial activation in central nociceptive regions.


Assuntos
Toxinas Botulínicas Tipo A , Analgésicos/uso terapêutico , Animais , Toxinas Botulínicas Tipo A/uso terapêutico , Formaldeído/uso terapêutico , Formaldeído/toxicidade , Dor/tratamento farmacológico , Ratos , Articulação Temporomandibular
12.
Braz Oral Res ; 36: e007, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35081225

RESUMO

Biofilm on acrylic resin dental prostheses may cause gingival inflammation. This study evaluated the influence of a silicon dioxide coating layer applied onto acrylic resin on the adhesion of microorganisms. Blocks (5 x 5 x 3 mm) of acrylic resin were evaluated for surface roughness and divided into two groups: control (CG) and coated with silicon dioxide (LG group). The specimens were evaluated by scanning electron microscopy (n = 1) and by contact angle analysis (n = 3). For the in situ study, 20 volunteers wore acrylic palatal devices containing three samples from each group (n = 60) for 2 days. The biofilm formed was quantified by metabolic activity and total biomass using the crystal violet assay. The results were subjected to Bartlett's normality test and Gamma model with random effect for the response variable (α = 5%). The mean contact angle of the coated group was significantly lower than that of the uncoated group (p < 0.05). The metabolic activity of microorganisms in the biofilm on the blocks treated with coating was significantly lower than that of control blocks (p = 0.02). Regarding the amount of extracellular matrix produced by the microorganisms, there was no difference between the CG and LG group (p = 0.05). The application of a silicon dioxide coating on acrylic resin reduced the activity of the polymicrobial biofilm formed in situ. This coating may be advantageous for patients with conventional complete dentures or implants made of acrylic resin and who have motor difficulties that prevent them from cleaning their prostheses properly.


Assuntos
Resinas Acrílicas , Bases de Dentadura , Biofilmes , Candida albicans , Humanos , Dióxido de Silício , Propriedades de Superfície
14.
Braz. oral res. (Online) ; 36: e081, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1394172

RESUMO

Abstract This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.

15.
Braz. oral res. (Online) ; 36: e007, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1355939

RESUMO

Abstract Biofilm on acrylic resin dental prostheses may cause gingival inflammation. This study evaluated the influence of a silicon dioxide coating layer applied onto acrylic resin on the adhesion of microorganisms. Blocks (5 x 5 x 3 mm) of acrylic resin were evaluated for surface roughness and divided into two groups: control (CG) and coated with silicon dioxide (LG group). The specimens were evaluated by scanning electron microscopy (n = 1) and by contact angle analysis (n = 3). For the in situ study, 20 volunteers wore acrylic palatal devices containing three samples from each group (n = 60) for 2 days. The biofilm formed was quantified by metabolic activity and total biomass using the crystal violet assay. The results were subjected to Bartlett's normality test and Gamma model with random effect for the response variable (α = 5%). The mean contact angle of the coated group was significantly lower than that of the uncoated group (p < 0.05). The metabolic activity of microorganisms in the biofilm on the blocks treated with coating was significantly lower than that of control blocks (p = 0.02). Regarding the amount of extracellular matrix produced by the microorganisms, there was no difference between the CG and LG group (p = 0.05). The application of a silicon dioxide coating on acrylic resin reduced the activity of the polymicrobial biofilm formed in situ. This coating may be advantageous for patients with conventional complete dentures or implants made of acrylic resin and who have motor difficulties that prevent them from cleaning their prostheses properly.

16.
J Mech Behav Biomed Mater ; 119: 104515, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33932754

RESUMO

This study investigated the influence of implant macrogeometry and bone type on insertion torque (IT), primary stability (ISQ), surface topography damage, and the amount of titanium (Ti) released during insertion. Forty implants with different macrogeometries (Facility - Cylindrical with spiral-shaped threads; Alvim - Tapered with buttress-shaped threads) were inserted into artificial bone types I-II and III-IV. Surface morphology was evaluated by Scanning Electron Microscope (SEM) and roughness parameters with Laser Scanning Confocal Microscopy (LSCM) before and after insertion (AI). Implant macrogeometry was characterized by LSCM. The chemical composition of bone beds was determined by SEM associated with Energy Dispersive X-Ray Spectroscopy. The amount of Ti released was analyzed with Energy Dispersive X-Ray Fluorescence. Alvim had greater IT and ISQ than Facility. Bone types I-II require higher IT of implants. Alvim also had greater internal threads angle, higher initial roughness, and significant reduction of roughness AI, compared to Facility. The functional surface height reduced AI, especially in flank and valley of threads. Height of surface roughness of Alvim and Facility implants was similar AI. Implants surface morphology changes and metallic particles on bone beds were observed after implant insertion, mainly into bone types III-IV. Implants inserted into bone types I-II showed less surface damage. Alvim implants released more Ti (37.52 ± 25.03 ppm) than Facility (11.66 ± 28.55 ppm) on bone types III-IV. The implant macrogeometry and bone types affect IT, ISQ, surface damage, and Ti amount released during insertion. Alvim implants were more wear susceptible, releasing higher Ti concentration during insertion into bone types III-IV.


Assuntos
Implantes Dentários , Titânio , Osso e Ossos , Planejamento de Prótese Dentária , Osseointegração , Propriedades de Superfície , Torque
17.
Materials (Basel) ; 14(7)2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33917610

RESUMO

Silane-coating strategy has been used to bind biological compounds to the titanium surface, thereby making implant devices biologically active. However, it has not been determined if the presence of the silane coating itself is biocompatible to osseointegration. The aim of the present study was to evaluate if silane-coating affects bone formation on titanium using a rabbit model. For this, titanium screw implants (3.75 by 6 mm) were hydroxylated in a solution of H2SO4/30% H2O2 for 4 h before silane-coating with 3-aminopropyltriethoxysilane (APTES). A parallel set of titanium screws underwent only the hydroxylation process to present similar acid-etched topography as a control. The presence of the silane on the surface was checked by x-ray photoelectron spectroscopy (XPS), with scanning electron microscopy (SEM) and atomic force microscopy (AFM). A total of 40 titanium screws were implanted in the tibia of ten New Zealand rabbits in order to evaluate bone-to-implant contact (BIC) after 3 weeks and 6 weeks of healing. Silane-coated surface presented higher nitrogen content in the XPS analysis, while micro- and nano-topography of the surface remained unaffected. No difference between the groups was observed after 3 and 6 weeks of healing (p > 0.05, independent t-test), although an increase in BIC occurred over time. These results indicate that silanization of a titanium surface with APTES did not impair the bone formation, indicating that this can be a reliable tool to anchor osteogenic molecules on the surface of implant devices.

18.
Front Nutr ; 8: 608095, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33681272

RESUMO

Background: Facial types may interfere in the oral health-related quality of life (OHRQoL) and masticatory performance of implant-retained mandibular overdenture (IMO) wearers. Purpose: Investigate the medium-term changes in the masticatory function (MF) and OHRQoL parameters of IMO users, as a function of facial pattern, anteroposterior skeletal discrepancy, and sex. Methods: Forty IMO users, most of them Caucasian (90%) with average age of 69.17 years were classified according to their facial pattern and antero-posterior discrepancy prior to rehabilitation. MF was evaluated by the multiple sieves method to determine the average particle size (X50), heterogeneity (B) and masticatory efficiency (ME, calculated as the percentage of material retained in the 5.6 and 2.8 mm sieves), using Masticatory performance (MP) and swallowing threshold (ST) tests. OHRQoL was measured by applying the dental impact on daily life (DIDL) questionnaire. The data were analyzed by Wilcoxon-paired tests to analyze changes in MF parameters over time, and mixed-effect multilevel regression models were employed to verify differences between groups. Results: Significant changes were still observed in the 3rd year for the ST test with improvements in B for Mesofacial and in time for Dolichofacial individuals, while ME_2.8 deteriorated for Brachyfacial participants. B values of Class I and male individuals improved and brachyfacial individuals still presented worse homogenization (B) than Mesofacial participants in both masticatory tests. Class II and III participants still showed improvements in ME_5.6 and time compared to Class I despite increases in X50. Class II individuals needed less cycles than Class I in the 3rd year. Brachyfacial participants scored lower in the Appearance domain than Mesofacial ones in the 3rd year. Dolichofacial participants and Class III patients scored lower in the Oral Comfort domain than Mesofacial and Class I, respectively. In addition, age influenced the Pain, Oral Comfort and General Performance domains in the 3rd year. Conclusions: Differences in facial morphology continue to influence the MF and OHRQoL outcomes in the 3rd year, and age influenced some OHRQoL domains. Brachyfacial individuals continue to benefit least from rehabilitation with IMO according to masticatory parameters.

19.
J Prosthet Dent ; 125(4): 683.e1-683.e8, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33583618

RESUMO

STATEMENT OF PROBLEM: Although luting space is related to the marginal fit of indirect restorations, information on its influence on the marginal fit and tensile strength of zirconia abutments bonded to titanium bases is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the influence of luting space on the marginal discrepancy and tensile strength of zirconia abutments bonded to a titanium base after dynamic loading. MATERIAL AND METHODS: Ninety implant replicas were embedded in resin blocks to attach 4-mm-high titanium luting bases. Zirconia abutments (Ceramill Zolid FX) were fabricated with different internal luting spaces: 25 µm (G25), 50 µm (G50), or 75 µm (G75). The zirconia abutments were cemented on the titanium bases by using a resin cement (Panavia F 2.0) under a constant load of 20 N. The marginal discrepancy and internal fit of 10 random specimens from each group were evaluated with a stereoscopic microscope at ×50 magnification. The remaining specimens were submitted to the tensile strength test in which half were evaluated after dynamic loading (1.2 million cycles of 200 N at 3.8 Hz) in a mechanical fatigue machine. The tensile strength test was performed using a pullout apparatus coupled to a universal testing machine at a crosshead speed of 0.5 mm/min. The mode of failure was determined by observation at ×50 magnification under a stereomicroscope and classified into adhesive or mixed. The groups were compared by using 2-way ANOVA and the Tukey HSD test (α=.05). RESULTS: Increase in the luting space did not influence the marginal discrepancy (P>.05). All zirconia abutments exhibited lower pullout strength after fatigue simulation (P<.05). G75 demonstrated lower tensile strength than G25 and G50 before and after loading (P<.05). Most failures were adhesive at the zirconia-cement interface. CONCLUSIONS: The increase of the luting space to 75 µm did not influence marginal discrepancy; however, it reduced the tensile strength of a zirconia abutment bonded to a titanium base.


Assuntos
Dente Suporte , Colagem Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Titânio , Zircônio
20.
Dent Mater ; 37(2): e69-e84, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33234316

RESUMO

OBJECTIVE: To evaluate the influence of hydrophilicity on the surface integrity of implants after insertion in low-density artificial bone and to determine the distribution of titanium (Ti) particles along the bone bed. METHODS: Forty-eight dental implants with different designs (Titamax Ex, Facility, Alvim, and Drive) and surface treatments (Neoporos® and Aqua™) were inserted into artificial bone blocks with density compatible with bone type III-IV. Hydrophobic Neoporos® surfaces were obtained by sandblasting and acid etching while hydrophilic Aqua™ surfaces were obtained by sandblasting, acid etching, and storage in an isotonic 0.9% NaCl solution. The surface integrity was evaluated by Scanning Electron Microscope (SEM) and the surface roughness parameters (Sa, Sp, Ssk, Sdr, Spk, Sk, and Svk) and surface area were measured with Laser Scanning Confocal Microscopy before and after installation. Bone beds were inspected with Digital Microscopy and micro X-Ray Fluorescence (µ-XRF) to analyze the metallic element distribution along the bone bed. RESULTS: Acqua™ implants had higher initial Sa and a pronounced reduction of Sa and Sp during insertion, compared to NeoPoros® implants. After insertion, Sa and Sp of Acqua™ and NeoPoros® implants equalized, differing only between designs of Acqua™ implants. Surface damage was observed after insertion, mainly in the apical region. Facility implants that are made of TiG5 released fewer debris particles, while the highest Ti intensity was detected in the cervical region of the Titamax Ex Acqua™ and Drive Acqua™ implants. SIGNIFICANCE: Physicochemical modifications to achieve surface hydrophilicity created a rougher surface that was more susceptible to surface alterations, resulting in more Ti particle release into the bone bed during surgical insertion. The higher Ti intensities detected in the cervical region of bone beds may be related to peri-implantitis and marginal bone resorption.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Interações Hidrofóbicas e Hidrofílicas , Implantes Experimentais , Microscopia Eletrônica de Varredura , Osseointegração , Propriedades de Superfície , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...